FTTH fiber-to-the-home solutions
Optical communication component solutions

Cold Solder Joints Causes, Detection Amp Prevention Guide

Browse technical resources about optical communication components, fiber technology, and network solutions.

  • Access Switch Loop Prevention

    Access Switch Loop Prevention

    STP prevents loops by blocking redundant paths, but misconfigurations or STP timer changes can cause loops to reform unexpectedly. Our existing design is quite simple, it consists of several switches acting as layer 2 (around 6-7) and all of them are connected to a switch through single interface trunk ports. This switch is connected to a firewall which is the gateway for all VLANS defined, which are extended in all the. The loop prevention feature of most switches is "Rapid Spanning Tree Protocol" or RSTP. It's normally impossible to get a bridging loop without another switch at the end. I have recently been told by a consultant that access layer loops can be prevented without spanning tree on host ports by using Layer 3 routing.

    [PDF Version]
  • Selection Guide for Carrier Backbone Network Grade SFP Optical Modules QSFP28

    Selection Guide for Carrier Backbone Network Grade SFP Optical Modules QSFP28

    A practical, engineer-friendly guide to choosing the right transceiver form factor by speed, port density, power, migration plan, and operational risk—built for 25G/100G networks in 2026. 25G SFP28 is the new access/server baseline; deploy it for port density and long-term value. Below, you will find comprehensive module comparisons, realistic market pricing, and precise vendor compatibility protocols to ensure a. 100G QSFP28 optical transceivers have become the backbone of modern hyperscale data centers, enabling high-density 100Gbps connectivity with significantly lower power consumption (3. 5–6W) than legacy CFP/CFP4 modules (6–24W). 25G is the new 10G; 100G (QSFP28) is the workhorse; design for migration plans to 400G/800G. In 2025, the optical transceiver market has shifted decisively.

    [PDF Version]
  • Causes of lightning strikes on PoE switches

    Causes of lightning strikes on PoE switches

    PoE powering is often used indoors because outdoor cabling requires unshielded network cables and causes PoE switches to be damaged by lightning strikes. By sending data and electrical power over a single cable, PoE simplifies installations and powers devices such as IP cameras, wireless access points and VoIP phones. But with great convenience comes vulnerability. Another key factor is that PoE combines two things on the same pairs: high-speed differential data signals and DC power delivery. It suddenly stops supplying power to the APs after a period of time. Feb 28 2020 14:35:50 hwPoePowerOff_active(l):CID=0x0-alarmID=0x08012266;PD powered off. (IfIndex=12, Interface="GE0/0/8") Outdoor cabling.


  • Selection Guide for New SFP Optical Modules for Surveillance Use

    Selection Guide for New SFP Optical Modules for Surveillance Use

    This guide demystifies SFP modules, exploring their design, types, key differences from related modules (like SFP+, SFP28, and QSFP), and actionable tips for selecting the right one for your needs. For network engineers, system integrators, and IT buyers, understanding how to choose the right SFP module for compatibility, speed, and distance is essential to ensuring stable and scalable infrastructure. SFP (Small Form-factor Pluggable) modules are hot-swappable optical or copper transceivers. SFP (Small Form-factor Pluggable) optical modules are compact, hot-pluggable transceivers that enable network equipment to connect seamlessly to fiber and copper links. Whether deploying in data centers, enterprise backbones, or storage networks, attention to detail during selection can prevent costly downtime and compatibility. Published: 2026 | Category: Network Hardware Knowledge Base / Optical Communications Core Keywords: SFP Module, SFP Transceiver, Small Form Factor Pluggable, What is SFP, SFP vs SFP+ Read Time: Approx. 25 Minutes Even in the era of Wi-Fi 7 and 5G, Optical Transceivers remain the backbone of the.

    [PDF Version]
  • Selection Guide for 400G Long-Distance Optical Transceivers for Distribution Network Automation

    Selection Guide for 400G Long-Distance Optical Transceivers for Distribution Network Automation

    This guide explains the differences between 400G QSFP-DD SR8, DR4, FR4, and LR4 transceivers, including transmission distance, fiber type, connector type, deployment scenarios, and how to choose the right module for your network. The definitive guide to selecting, deploying, and maximizing 400G optical transceivers for network architects, procurement managers, and operations teams building the infrastructure that powers today's AI, cloud, and carrier networks. Many early adopters of 400G QSFP-DD faced similar challenges—just as the industry did during the transition to 10G a decade ago. With its ability to deliver high bandwidth, low latency, and scalable deployment, it has been adopted widely by hyperscale data centers and large enterprises. Several form factors and standards exist within the 400G.

    [PDF Version]
  • 800G Optical Module OSFP Operation Guide

    800G Optical Module OSFP Operation Guide

    Manuals and User Guides for FS OSFP-SR8-800G. We have 2 FS OSFP-SR8-800G manuals available for free PDF download: Testing Manual, Installation Notes Fs OSFP-SR8-800G Pdf User Manuals. View online or download Fs OSFP-SR8-800G Testing. The FS OSFP-SR8-800G is an 800Gb/s 2x400Gb/s Twin-port OSFP transceiver that supports InfiniBand or Ethernet protocols. This SR8 multimode, parallel, 8-channel transceiver uses two, 4-channel MPO-12/APC optical connectors at 400Gb/s each. The modules comply with the OSFP MSA configuration with integrated closed. The Cisco® OSFP 800G transceiver modules provide 800 Gigabit Ethernet (GE), 2x 400GE, 4x 200GE, and 8x 100GE connectivity options, complying with the Octal Small Form Factor Pluggable (OSFP) MSA for pluggable transceivers. It carries a built-in aluminum heat sink that adds visible bulk. Removing QSFP-DD and QSFP Transceiver Modules 5.

    [PDF Version]
  • Adjustable distribution box guide rail

    Adjustable distribution box guide rail

    The DIN-rail can be adjustable, and the two terminals (ground connection and zero connection) in the box are easy for the user wiring and routing. Guide rails are used to guide the products being con-veyed and also to prevent them from falling off the con-veyor. The conveyor system includes a versatile system of guide rails and guide rail brackets which make it pos-sible to accommodate many different product sizes and shapes. Additional mounting levels, different functions such as support rails or C rails - individual configuration knows no limits. Rail for flexible interior installation on a 25 mm pitch pattern in AX compact enclosures. Providing fast and repeatable guide setups.


  • How many optical fibers can be connected to an FC cold connector

    How many optical fibers can be connected to an FC cold connector

    It typically supports 12, 16, or 24 fibers, but can go up to 72 fibers. They are widely used in high-density cabling environments such as data centers, supporting 40G, 100G, and 400G network systems. Fiber connectors are essential components used to terminate optical fiber cables, creating non-permanent or removable fiber joints for connecting fiber-coupled devices. Unlike fiber splicing, which is permanent, connectors allow for easy connection and disconnection of cables, making them ideal for maintenance and flexibility in. Threaded FC/APC connectors are designed for high-vibration environments and minimal back reflections.


  • Energy Saving in Cold Aisle Cabinets

    Energy Saving in Cold Aisle Cabinets

    These cabinets are designed to isolate and contain the cold air that flows into server racks, thereby creating a tightly controlled environment that allows for more efficient cooling and energy usage. An enormous amount of energy is used every day to maintain an acceptable intake. Cold aisle and hot aisle containment systems have emerged as essential strategies in modern data center airflow management. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability.


More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +86 13816583346
Address No. 26 Heshun Middle Road, Economic Development Zone, Hai'an City, Jiangsu Province, China

Send an Inquiry