FTTH fiber-to-the-home solutions
Optical communication component solutions

Centralized Protection Amp Control – Uncovering The

Browse technical resources about optical communication components, fiber technology, and network solutions.

  • Lightning protection wires for power transmission lines and optical cables

    Lightning protection wires for power transmission lines and optical cables

    OPGW stands for Optical Ground Wire, a type of cable used in overhead power lines that not only provides grounding and lightning protection, but also houses optic fibers for data transmission. When people ask, “what is OPGW?” they are often curious about how a single cable can serve such a dual. An optical ground wire (also known as an OPGW or, in the IEEE standard, an optical fiber composite overhead ground wire) is a type of cable that is used in overhead power lines.


  • Relay protection reclosing charging time

    Relay protection reclosing charging time

    Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is generally between 5-10 seconds, while for low-voltage circuit breakers, charging is typically completed within a few hundred milliseconds. Impact of Charging Time on Power. Protective relay Operation: For instanta-neous reclosure, contacts must open within 10 cycles or less after breaker is tripped to insure the relay circuit is de-energized be-fore reclosing breaker. Mechanically Trip Free Breakers: Latch checking switch. Automatic Reclosing (ARC) is a protection relay in power systems that attempts to reclose a circuit breaker after a fault is cleared, distinguishing between ​transient faults​ (e., lightning strikes, tree contact) and ​permanent faults​ (e. The closing time delay is a settable parameter and referred to as the dead time of the corresponding AR-shot. The root cause of these failures was missing zero-crossings in the line current during protection trips that were preceded by line energizations.

    [PDF Version]
  • 24V Relay Protection Without Exiting the Cabinet

    24V Relay Protection Without Exiting the Cabinet

    The Risk: Relay coils generate high-voltage spikes (Back EMF) when turned off, which can destroy PLCs. The Best Practice: Use plug-in protection modules with Relay Sockets for easier maintenance. The devices feature the lowest power loss on the market and an impressive performance in severe conditions. The EPD24 offer selective overcurrent protection for the loads connected and react to short circuit or overload more. This application example explains how 24 V DC can be protected, multiplicated and distributed in the I/O environment. On account of the flexible and modular layout in the I/O system, the required space in the control. Electronic protection modules thus provide much greater safety: They are able to detect overloads quickly and then switch off only the faulty machine parts from the power supply. This safety relay embeds 1 control output, 4 NO safety. The culprit is often an invisible electrical phenomenon known as Back EMF (Electromotive Force) caused by switching inductive loads—specifically, your relay coils.

    [PDF Version]
  • European Three-Sequence Electrical Protection Tester

    European Three-Sequence Electrical Protection Tester

    The TRES is a comprehensive, portable three-phase test system capable of testing all types of electromechanical and digital protective relays. With high power outputs packaged in an extremely compact and rugged system, the TRES has a tremendous power-to-weight ratio. The SVERKER 900 relay and substation test system is the engineer's ultimate toolbox, addressing the increasing need for three-phase testing in. Phase tester, phase sequence indicator, socket tester and current clamp with test functions The DUSPOL® brand stands for safety in the electrical trade – for 75 years! Continuous developments in construction and design as well as the high manufacturing quality of electronic test equipment made by. Megger's SVERKER 750/780 offers secondary relay testing and primary injection for electrical distribution substations, renewable power generation stations, and industrial applications. Primary and secondary injection in complete ranges from low to high amplitudes with high precision. -Standard 4-phase voltage and 3-phase current output.

    [PDF Version]
  • Relay protection affected by vibration

    Relay protection affected by vibration

    Relays are mechanical devices, and as such, they are vulnerable to mechanical stress and vibration. Continuous or excessive vibration can cause the internal components, such as the armature and contacts, to become misaligned or wear out prematurely. Relays are subjected to vibration and mechanical shock due to operating. My application for the relay is to cut off downstream power with a µController, hence the 3V coil. The out-comes obtained during the fault period reveals that the waveform of three-phase current changes greatly, and the amplitude of three-phase current at power supply side. Relays are the protection and switching devices in most of the control processes or equipment.